Skip to main content

raid - HP SmartArray P400: How to repair failed logical drive?



I have a HP Server with SmartArray P400 controller (incl. 256 MB Cache/Battery Backup) with a logicaldrive with replaced failed physicaldrive that does not rebuild.




This is how it looked when I detected the error:




~# /usr/sbin/hpacucli ctrl slot=0 show config
Smart Array P400 in Slot 0 (Embedded) (sn: XXXX)

array A (SATA, Unused Space: 0 MB)
logicaldrive 1 (698.6 GB, RAID 1, OK)
physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SATA, 750 GB, OK)

physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SATA, 750 GB, OK)

array B (SATA, Unused Space: 0 MB)
logicaldrive 2 (2.7 TB, RAID 5, Failed)
physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SATA, 750 GB, OK)
physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SATA, 750 GB, OK)
physicaldrive 2I:1:5 (port 2I:box 1:bay 5, SATA, 750 GB, OK)
physicaldrive 2I:1:6 (port 2I:box 1:bay 6, SATA, 750 GB, Failed)
physicaldrive 2I:1:7 (port 2I:box 1:bay 7, SATA, 750 GB, OK)


unassigned
physicaldrive 2I:1:8 (port 2I:box 1:bay 8, SATA, 750 GB, OK)
~#


I thought that I had drive 2I:1:8 configured as a spare for Array A and Array B, but it seems this was not the case :-(. I noticed the problem due to I/O errors on the host, even if only 1 physicaldrive of the RAID5 is failed.



Does someone know why this could happen? The logicaldrive should go into "Degraded" mode but still be fully accessible from the host os!?



I first tried to add the unassigned drive 2I:1:8 as a spare to logicaldrive 2, but this was not possible:





~# /usr/sbin/hpacucli ctrl slot=0 array B add spares=2I:1:8
Error: This operation is not supported with the current configuration.
Use the "show" command on devices to show additional details
about the configuration.
~#


Interestingly it is possible to add the unassigned drive to the first array without problems. I thought maybe the controller put the array into "failed" state due to the missing spare and protects failed arrays from modification. So I tried was to reenable the logicaldrive (to add the spare afterwards):





~# /usr/sbin/hpacucli ctrl slot=0 ld 2 modify reenable
Warning: Any previously existing data on the logical drive may not
be valid or recoverable. Continue? (y/n) y

Error: This operation is not supported with the current configuration.
Use the "show" command on devices to show additional details
about the configuration.
~#



But as you can see, re-enabling the logicaldrive this was not possible.



Now I replaced the failed drive by hotswapping it with the unassigned drive. The status now looks like this:




~# /usr/sbin/hpacucli ctrl slot=0 show config
Smart Array P400 in Slot 0 (Embedded) (sn: XXXX)


array A (SATA, Unused Space: 0 MB)
logicaldrive 1 (698.6 GB, RAID 1, OK)
physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SATA, 750 GB, OK)
physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SATA, 750 GB, OK)

array B (SATA, Unused Space: 0 MB)
logicaldrive 2 (2.7 TB, RAID 5, Failed)
physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SATA, 750 GB, OK)
physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SATA, 750 GB, OK)
physicaldrive 2I:1:5 (port 2I:box 1:bay 5, SATA, 750 GB, OK)

physicaldrive 2I:1:6 (port 2I:box 1:bay 6, SATA, 750 GB, OK)
physicaldrive 2I:1:7 (port 2I:box 1:bay 7, SATA, 750 GB, OK)
~#


The logical drive is still not accessible. Why is it not rebuilding?



What can I do?



FYI, this is the configuration of my controller:





~# /usr/sbin/hpacucli ctrl slot=0 show
Smart Array P400 in Slot 0 (Embedded)
Bus Interface: PCI
Slot: 0
Serial Number: XXXX
Cache Serial Number: XXXX
RAID 6 (ADG) Status: Enabled
Controller Status: OK

Chassis Slot:
Hardware Revision: Rev E
Firmware Version: 5.22
Rebuild Priority: Medium
Expand Priority: Medium
Surface Scan Delay: 15 secs
Surface Analysis Inconsistency Notification: Disabled
Raid1 Write Buffering: Disabled
Post Prompt Timeout: 0 secs
Cache Board Present: True

Cache Status: OK
Accelerator Ratio: 25% Read / 75% Write
Drive Write Cache: Disabled
Total Cache Size: 256 MB
No-Battery Write Cache: Disabled
Cache Backup Power Source: Batteries
Battery/Capacitor Count: 1
Battery/Capacitor Status: OK
SATA NCQ Supported: True
~#



Thanks for you help in advance.


Answer



The answer is not pleasant. There's a high probability that your array is in a "waiting for rebuild" state, where there's another failing disk in the RAID5 array set that's preventing the recovery from completing. This is why you should avoid RAID5 these days. It doesn't help that these are SATA drives... The likelihood of problems is even higher. Try powering the system off (letting the drives spin down) and powering back on. Follow the prompts at the BIOS array screen and choose the F2 option to "reenable all logical drives". This may kickstart the rebuild process.



Otherwise, it's a rebuild/recovery with new disks.


Comments

Popular posts from this blog

linux - iDRAC6 Virtual Media native library cannot be loaded

When attempting to mount Virtual Media on a iDRAC6 IP KVM session I get the following error: I'm using Ubuntu 9.04 and: $ javaws -version Java(TM) Web Start 1.6.0_16 $ uname -a Linux aud22419-linux 2.6.28-15-generic #51-Ubuntu SMP Mon Aug 31 13:39:06 UTC 2009 x86_64 GNU/Linux $ firefox -version Mozilla Firefox 3.0.14, Copyright (c) 1998 - 2009 mozilla.org On Windows + IE it (unsurprisingly) works. I've just gotten off the phone with the Dell tech support and I was told it is known to work on Linux + Firefox, albeit Ubuntu is not supported (by Dell, that is). Has anyone out there managed to mount virtual media in the same scenario?

hp proliant - Smart Array P822 with HBA Mode?

We get an HP DL360 G8 with an Smart Array P822 controller. On that controller will come a HP StorageWorks D2700 . Does anybody know, that it is possible to run the Smart Array P822 in HBA mode? I found only information about the P410i, who can run HBA. If this is not supported, what you think about the LSI 9207-8e controller? Will this fit good in that setup? The Hardware we get is used but all original from HP. The StorageWorks has 25 x 900 GB SAS 10K disks. Because the disks are not new I would like to use only 22 for raid6, and the rest for spare (I need to see if the disk count is optimal or not for zfs). It would be nice if I'm not stick to SAS in future. As OS I would like to install debian stretch with zfs 0.71 as file system and software raid. I have see that hp has an page for debian to. I would like to use hba mode because it is recommend, that zfs know at most as possible about the disk, and I'm independent from the raid controller. For us zfs have many benefits,

apache 2.2 - Server Potentially Compromised -- c99madshell

So, low and behold, a legacy site we've been hosting for a client had a version of FCKEditor that allowed someone to upload the dreaded c99madshell exploit onto our web host. I'm not a big security buff -- frankly I'm just a dev currently responsible for S/A duties due to a loss of personnel. Accordingly, I'd love any help you server-faulters could provide in assessing the damage from the exploit. To give you a bit of information: The file was uploaded into a directory within the webroot, "/_img/fck_uploads/File/". The Apache user and group are restricted such that they can't log in and don't have permissions outside of the directory from which we serve sites. All the files had 770 permissions (user rwx, group rwx, other none) -- something I wanted to fix but was told to hold off on as it wasn't "high priority" (hopefully this changes that). So it seems the hackers could've easily executed the script. Now I wasn't able