Skip to main content

nameserver - Vanity name servers with .no domains




I created vanity name servers e.g. ns1.example.com and ns2.example.com that are just maskеа and are pointed to rackspace free dns service. In other words ns1.example.com points to dns1.stabletransit.com and ns2.example.com points to dns2.stabletransit.com(stabletransit.com are rackspace's nameservers). In general it works fine and I can forward domains to ns1.example.com and they will work correctly and redirected to dns1.stabletransit.com. However for .no(norway) domains I stumbled into the following error:



 The nameserver ns1.example.com is not correctly configured. It has the following NS records in the zone file for somedomain.no:

dns1.stabletransit.com dns2.stabletransit.com

This does not correspond with the nameservers you have entered, which are:

ns1.example.com ns2.example.com


The list you enter must be identical to the list of NS records returned by each nameserver on the list.

For .no domains the nameservers must be configured correctly before the delegation can be completed. Not all ISPs are aware of this. Please contact the administrators of the nameservers you are trying to use, and ask them to create a valid zone file for somedomain.no on all the nameservers.


This is the error message that I got when I try to point .no domains to my vanity name servers. I will be thanlful if someone can expain why this happens and how can I fix it. As far as I understand this is a correct way to mask name servers by creating vanity name servers, so I'm not sure where I'm mistaken.



Thanks in advance for any help!


Answer



This is because the "real" nameserver for the domain tells that dns1.sabletransit.com and dns2.stabletransit.com are the authoritative nameservers for this domain. (NS record)




The .no registry seems to check this.



I don't think rackspace free dns allows you to change this, so I don't think there's anything you can do.


Comments

Popular posts from this blog

iLO 3 Firmware Update (HP Proliant DL380 G7)

The iLO web interface allows me to upload a .bin file ( Obtain the firmware image (.bin) file from the Online ROM Flash Component for HP Integrated Lights-Out. ) The iLO web interface redirects me to a page in the HP support website ( http://www.hp.com/go/iLO ) where I am supposed to find this .bin firmware, but no luck for me. The support website is a mess and very slow, badly categorized and generally unusable. Where can I find this .bin file? The only related link I am able to find asks me about my server operating system (what does this have to do with the iLO?!) and lets me download an .iso with no .bin file And also a related question: what is the latest iLO 3 version? (for Proliant DL380 G7, not sure if the iLO is tied to the server model)

linux - How can I get my mediawiki to stop thinking I have cookies disabled?

I've searched half a day for how to resolve this issue, and can't figure it out. Shortly after I made my wiki a simple private wiki according to the instructions at Mediawiki's website, it started giving me this weird login error message: Wiki uses cookies to log in users. You have cookies disabled. Please enable them and try again. If I remove those private wiki settings, the error disappears, even if I try logging in. But I need it to be a private wiki for only my team. So what do I do? Here's what I've done so far. Just to be safe, after ever change, I try rebooting Apache using: sudo /etc/init.d/apache2 restart In my php.ini file, I have the following set: session.save_path = "/var/lib/php5" session.cookie_secure = secure session.cookie_path = /tmp session.cookie_domain = my server's internal URL (should I even set this? this field was blank before, but not commented out) session.referer_check = Off I ran the following to ensure that the fold...

hp proliant - Smart Array P822 with HBA Mode?

We get an HP DL360 G8 with an Smart Array P822 controller. On that controller will come a HP StorageWorks D2700 . Does anybody know, that it is possible to run the Smart Array P822 in HBA mode? I found only information about the P410i, who can run HBA. If this is not supported, what you think about the LSI 9207-8e controller? Will this fit good in that setup? The Hardware we get is used but all original from HP. The StorageWorks has 25 x 900 GB SAS 10K disks. Because the disks are not new I would like to use only 22 for raid6, and the rest for spare (I need to see if the disk count is optimal or not for zfs). It would be nice if I'm not stick to SAS in future. As OS I would like to install debian stretch with zfs 0.71 as file system and software raid. I have see that hp has an page for debian to. I would like to use hba mode because it is recommend, that zfs know at most as possible about the disk, and I'm independent from the raid controller. For us zfs have many benefits, ...