Skip to main content

Monitoring PostgreSQL replication with Nagios and check_postgres shows intermittent delay

I have a master and hot standby setup with PostgreSQL 9.3, and I'm attempting to monitor the state of replication on the standby using the check_postgres tool and the "hot_standby_delay" action. This seems to work by calculating the difference in bytes between the xlog position on the master and the standby.



In numerous online examples I have seen warning and critical thresholds for this in the < 1MB range. The exact command we are using in Nagios is:



/usr/local/bin/check_postgres.pl --action=hot_standby_delay --host=$HOSTNOTES$,$HOSTADDRESS$ --port=5432 --dbname=monitoring --dbuser=monitoring --dbpass=monitoring --warning=1000000 --critical=5000000



Which should set a warning at roughly 1MB and an outage at roughly 5MB. However, on our servers we routinely see it spike to a high level, like this:



[1417719713] SERVICE ALERT: host;PostgreSQL: Replication Delay;CRITICAL;SOFT;1;POSTGRES_HOT_STANDBY_DELAY CRITICAL: DB "monitoring" (host:host.example.com) 121175880

[1417719773] SERVICE ALERT: host;PostgreSQL: Replication Delay;CRITICAL;SOFT;2;POSTGRES_HOT_STANDBY_DELAY CRITICAL: DB "monitoring" (host:host.example.com) 132780968
[1417719833] SERVICE ALERT: host;PostgreSQL: Replication Delay;CRITICAL;SOFT;3;POSTGRES_HOT_STANDBY_DELAY CRITICAL: DB "monitoring" (host:host.example.com) 21412936


Followed up on the next Nagios check with:



[1417719893] SERVICE ALERT: host;PostgreSQL: Replication Delay;OK;SOFT;4;POSTGRES_HOT_STANDBY_DELAY OK: DB "monitoring" (host:host.example.com) 0


So in the general sense it seems that replication is working (and indeed, performing a data update on the master sees immediate results on the standby).




Unfortunately this scenario makes the monitoring useless since it is triggering a false positive many times a day. From what I've found between the documentation and other examples of using this, this result is not typical, and most people are able to set a threshold of 1MB or less and only see errors when there are in fact errors.



Does anybody have any idea of what I could try with the configuration to remedy this? On this particular install we have changed only a few parameters, and of those, only wal_keep_segments seems even remotely related (and we have that set to 128).



Both master and standby are hosted in EC2 in the same availability zone and there don't seem to be any communication delays between them. This is also a very low-traffic database so I am uncertain as to how the xlog delta could be that far off to begin with, unless I am missing some very critical fact.

Comments

Popular posts from this blog

linux - Awstats - outputting stats for merged Access_logs only producing stats for one server's log

I've been attempting this for two weeks and I've accessed countless number of sites on this issue and it seems there is something I'm not getting here and I'm at a lost. I manged to figure out how to merge logs from two servers together. (Taking care to only merge the matching domains together) The logs from the first server span from 15 Dec 2012 to 8 April 2014 The logs from the second server span from 2 Mar 2014 to 9 April 2014 I was able to successfully merge them using the logresolvemerge.pl script simply enermerating each log and > out_putting_it_to_file Looking at the two logs from each server the format seems exactly the same. The problem I'm having is producing the stats page for the logs. The command I've boiled it down to is /usr/share/awstats/tools/awstats_buildstaticpages.pl -configdir=/home/User/Documents/conf/ -config=example.com awstatsprog=/usr/share/awstats/wwwroot/cgi-bin/awstats.pl dir=/home/User/Documents/parced -month=all -year=all...

iLO 3 Firmware Update (HP Proliant DL380 G7)

The iLO web interface allows me to upload a .bin file ( Obtain the firmware image (.bin) file from the Online ROM Flash Component for HP Integrated Lights-Out. ) The iLO web interface redirects me to a page in the HP support website ( http://www.hp.com/go/iLO ) where I am supposed to find this .bin firmware, but no luck for me. The support website is a mess and very slow, badly categorized and generally unusable. Where can I find this .bin file? The only related link I am able to find asks me about my server operating system (what does this have to do with the iLO?!) and lets me download an .iso with no .bin file And also a related question: what is the latest iLO 3 version? (for Proliant DL380 G7, not sure if the iLO is tied to the server model)

hp proliant - Smart Array P822 with HBA Mode?

We get an HP DL360 G8 with an Smart Array P822 controller. On that controller will come a HP StorageWorks D2700 . Does anybody know, that it is possible to run the Smart Array P822 in HBA mode? I found only information about the P410i, who can run HBA. If this is not supported, what you think about the LSI 9207-8e controller? Will this fit good in that setup? The Hardware we get is used but all original from HP. The StorageWorks has 25 x 900 GB SAS 10K disks. Because the disks are not new I would like to use only 22 for raid6, and the rest for spare (I need to see if the disk count is optimal or not for zfs). It would be nice if I'm not stick to SAS in future. As OS I would like to install debian stretch with zfs 0.71 as file system and software raid. I have see that hp has an page for debian to. I would like to use hba mode because it is recommend, that zfs know at most as possible about the disk, and I'm independent from the raid controller. For us zfs have many benefits, ...