hp - Proliant ML310e Gen8 Smart Array Predicted Failure Issue with SSD

This is a question related to this one:



Third-party SSD solutions in ProLiant Gen8 servers



but not covered by the question or the answers.




I have an OCZ 120 gig SSD as system drive on a Proliant ML310e Gen8 server, sitting on SATA port 6. In order to use that port (on the motherboard) for the SSD, I must set the SATA controller to SMART Array controller. This gives me all 4 bays for a RAID set of HDD drives.



So far, so good. I've also installed Win Server 2008 R2 on the system drive and all works well.



BUT - when I chack the SMART Array, it say "predicted failure of drive 0 (SSD)". I have checked and verified the actual SMART settings for the SSD, and the drive is 100% OK. It's brand new, and the SMART settings have been verified as 100% OK by OCZ support.



I cannot clear this error on the HP diagnostic side, and at OCZ's suggestion I have been trying to figure out how to turn off SMART diagnostics on the HP, to no avail.



SO - how can I either clear the HP SMART Array (incorrect) diagnostic reading of the OCZ SSD SMART data, or else how can I turn off the HP reading the SMART stats off the SSD.




I realize this is entirely my own fault for not wanting to spent $1000+ on an HP branded SSD, but the OCZ one is working perfectly fine. It's just the OCZ version of SMART is not the same as HP's idea of SMART for SSD drive stats, and I'm really tired of the yellow blinking "system degraded" front panel light.



And yes, I've already been told "put black electrical tape over it". :-)



But I'd really like to find a better solution. This SMART stuff was supposed to be quasi-universal.

Comments

Popular posts from this blog

linux - Awstats - outputting stats for merged Access_logs only producing stats for one server's log

I've been attempting this for two weeks and I've accessed countless number of sites on this issue and it seems there is something I'm not getting here and I'm at a lost. I manged to figure out how to merge logs from two servers together. (Taking care to only merge the matching domains together) The logs from the first server span from 15 Dec 2012 to 8 April 2014 The logs from the second server span from 2 Mar 2014 to 9 April 2014 I was able to successfully merge them using the logresolvemerge.pl script simply enermerating each log and > out_putting_it_to_file Looking at the two logs from each server the format seems exactly the same. The problem I'm having is producing the stats page for the logs. The command I've boiled it down to is /usr/share/awstats/tools/awstats_buildstaticpages.pl -configdir=/home/User/Documents/conf/ -config=example.com awstatsprog=/usr/share/awstats/wwwroot/cgi-bin/awstats.pl dir=/home/User/Documents/parced -month=all -year=all...

iLO 3 Firmware Update (HP Proliant DL380 G7)

The iLO web interface allows me to upload a .bin file ( Obtain the firmware image (.bin) file from the Online ROM Flash Component for HP Integrated Lights-Out. ) The iLO web interface redirects me to a page in the HP support website ( http://www.hp.com/go/iLO ) where I am supposed to find this .bin firmware, but no luck for me. The support website is a mess and very slow, badly categorized and generally unusable. Where can I find this .bin file? The only related link I am able to find asks me about my server operating system (what does this have to do with the iLO?!) and lets me download an .iso with no .bin file And also a related question: what is the latest iLO 3 version? (for Proliant DL380 G7, not sure if the iLO is tied to the server model)

hp proliant - Smart Array P822 with HBA Mode?

We get an HP DL360 G8 with an Smart Array P822 controller. On that controller will come a HP StorageWorks D2700 . Does anybody know, that it is possible to run the Smart Array P822 in HBA mode? I found only information about the P410i, who can run HBA. If this is not supported, what you think about the LSI 9207-8e controller? Will this fit good in that setup? The Hardware we get is used but all original from HP. The StorageWorks has 25 x 900 GB SAS 10K disks. Because the disks are not new I would like to use only 22 for raid6, and the rest for spare (I need to see if the disk count is optimal or not for zfs). It would be nice if I'm not stick to SAS in future. As OS I would like to install debian stretch with zfs 0.71 as file system and software raid. I have see that hp has an page for debian to. I would like to use hba mode because it is recommend, that zfs know at most as possible about the disk, and I'm independent from the raid controller. For us zfs have many benefits, ...