Skip to main content

storage - ML350 G5 - upgrade hot swap drives to 6 Gb/s?



I support a non profit. They got an ML350 G5 donated to them and I immediately put it to good use for them :) It came with four HP 300GB 15K SAS drives - and of course, they have all now failed. I have been replacing the drives and they are all 6Gb/s drives, but the HP controller in the ML350 is a 3Gb/s controller. I have a nice 8 port LSI MegaRAID SAS controller sitting here with battery backup and everything - can I just swap out the controllers and expect everything to work?



I haven't found much about the differences between 3 and 6 Gb/s SAS interface from a physical layer. As near as I can tell, it should work just fine. I'm just curious if anyone has any experience doing this.



I'm not hung up on the drives being hot swappable, so if not I may just see if I can physically alter the case, toss the HP drive cage and stuff a different cage or mounting system in there to accommodate the better controller with the newer drives.




Ugh - now I remember why I prefer white box servers for one-off or small business vs. the "big boys" like HP, Dell, etc...



And anyone have a good source for rails for this thing? The HP prices are ridiculous - I could build another server for what they want for rails!


Answer



That's a lot to address. I'd keep the existing Smart Array p400 controller in place for now, provided it has a working battery-backed cache unit. Otherwise, your LSI will work, but it's not ideal.



The on-disk RAID formats are different, so this means a full rebuild. You won't be able to preserve your data if you do what you're proposing.



As for 3G versus 6G, it does not make a difference unless you're dealing with SAS expanders or solid-state drives. You won't see any difference in performance in your case.




I tend to think that HP controllers run better in their servers. I'm also not a fan of LSI's management software (MegaCLI is awful). Using LSI HBA cards for other solutions makes sense, though. Your best bet in this case is to make sure you have an HP P400 controller with BBWC cache (here's why). If you don't have the cache, your path of least resistance is to obtain one.



That way, you can be sure that your backplane, alerts, LED indicators and integration with system monitoring all work properly.



As for rails, check:
http://www.racksolutions.com/hp/racking-hp/ml350


Comments

Popular posts from this blog

linux - iDRAC6 Virtual Media native library cannot be loaded

When attempting to mount Virtual Media on a iDRAC6 IP KVM session I get the following error: I'm using Ubuntu 9.04 and: $ javaws -version Java(TM) Web Start 1.6.0_16 $ uname -a Linux aud22419-linux 2.6.28-15-generic #51-Ubuntu SMP Mon Aug 31 13:39:06 UTC 2009 x86_64 GNU/Linux $ firefox -version Mozilla Firefox 3.0.14, Copyright (c) 1998 - 2009 mozilla.org On Windows + IE it (unsurprisingly) works. I've just gotten off the phone with the Dell tech support and I was told it is known to work on Linux + Firefox, albeit Ubuntu is not supported (by Dell, that is). Has anyone out there managed to mount virtual media in the same scenario?

ubuntu - Monitoring CPU, Mem, disk, on a single server

I've been looking for a simple starter solution for monitoring my [currently] single server hosted solution. Other than Nagios and similar, are there other good (simple) solutions people are using? Answer Everything depends on what you want. For example Munin is very simple, you can install and configure it in less then 10 minutes (on one server), it can sends alarms, make graphs from monitoring cpu, mem. apache connections, eaccellerator, disk io and many many more (it has many plugins). But if you are planning in future get some more machines, munin may not be enough. For example in munin you cant monitor state of individual processes, can't monitor changes in files (for security purpose). So if you wanna only see what is the utilization of basics parameters on your server and don't plan to buy some more servers Munin is what you are looking for, but if you wanna be alarmed when some of your service is down, take more control on what is happeninig on...

hp proliant - Smart Array P822 with HBA Mode?

We get an HP DL360 G8 with an Smart Array P822 controller. On that controller will come a HP StorageWorks D2700 . Does anybody know, that it is possible to run the Smart Array P822 in HBA mode? I found only information about the P410i, who can run HBA. If this is not supported, what you think about the LSI 9207-8e controller? Will this fit good in that setup? The Hardware we get is used but all original from HP. The StorageWorks has 25 x 900 GB SAS 10K disks. Because the disks are not new I would like to use only 22 for raid6, and the rest for spare (I need to see if the disk count is optimal or not for zfs). It would be nice if I'm not stick to SAS in future. As OS I would like to install debian stretch with zfs 0.71 as file system and software raid. I have see that hp has an page for debian to. I would like to use hba mode because it is recommend, that zfs know at most as possible about the disk, and I'm independent from the raid controller. For us zfs have many benefits, ...